Safety Light Curtains (XUSL)

Light curtains protect an opening that has to stay open — material infeed, an operator loading position, a robot cell entrance. Resolution defines what the barrier detects: 14 mm for finger protection close to the hazard, 30 mm for hand protection at a distance calculated from the stopping time of the machine. Muting and blanking allow product to pass while a person still cannot.

Safety Light Curtains (XUSL)
Key characteristics
  • Type 2 and Type 4 barriers to IEC 61496
  • 14, 20 and 30 mm resolution; protected heights from 150 mm upward
  • Muting, fixed and floating blanking functions
  • Integrated or external muting lamp and diagnostics
  • Cascadable transmitters/receivers for multi-side protection
Typical applications

Operator access openings on presses, robot cells and packaging lines